Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 48
Filtrar
1.
Anal Biochem ; 684: 115374, 2024 01 01.
Artigo em Inglês | MEDLINE | ID: mdl-37914005

RESUMO

The overexpression and/or amplification of the HER2/neu oncogene has been proposed as a prognostic marker in breast cancer. The detection of the related peptide HER2 remains a grand challenge in cancer diagnosis and for therapeutic decision-making. Here, we used a biosensing device based on Bloch Surface Waves excited on a one-dimensional photonic crystal (1DPC) as valid alternative to standard techniques. The 1DPC was optimized to operate in the visible spectrum and the biosensor optics has been designed to combine label-free and fluorescence operation modes. This feature enables a real-time monitoring of a direct competitive assay using detection mAbs conjugated with quantum dots for an accurate discrimination in fluorescence mode between HER2-positive/negative human plasma samples. Such a competitive assay was implemented using patterned alternating areas where HER2-Fc chimera and reference molecules were bio-conjugated and monitored in a multiplexed way. By combining Label-Free and fluorescence detection analysis, we were able to tune the parameters of the assay and provide an HER2 detection in human plasma in less than 20 min, allowing for a cost-effective assay and rapid turnaround time. The proposed approach offers a promising technique capable of performing combined label-free and fluorescence detection for both diagnosis and therapeutic monitoring of diseases.


Assuntos
Técnicas Biossensoriais , Receptor ErbB-2 , Humanos , Receptor ErbB-2/sangue , Fluorescência , Anticorpos Monoclonais/química , Dispositivos Lab-On-A-Chip , Análise Serial de Proteínas
2.
J Biol Eng ; 17(1): 60, 2023 Sep 28.
Artigo em Inglês | MEDLINE | ID: mdl-37770970

RESUMO

BACKGROUND: Calcific aortic valve disease (CAVD) causes an increasing health burden in the 21st century due to aging population. The complex pathophysiology remains to be understood to develop novel prevention and treatment strategies. Microphysiological systems (MPSs), also known as organ-on-chip or lab-on-a-chip systems, proved promising in bridging in vitro and in vivo approaches by applying integer AV tissue and modelling biomechanical microenvironment. This study introduces a novel MPS comprising different micropumps in conjunction with a tissue-incubation-chamber (TIC) for long-term porcine and human AV incubation (pAV, hAV). RESULTS: Tissue cultures in two different MPS setups were compared and validated by a bimodal viability analysis and extracellular matrix transformation assessment. The MPS-TIC conjunction proved applicable for incubation periods of 14-26 days. An increased metabolic rate was detected for pulsatile dynamic MPS culture compared to static condition indicated by increased LDH intensity. ECM changes such as an increase of collagen fibre content in line with tissue contraction and mass reduction, also observed in early CAVD, were detected in MPS-TIC culture, as well as an increase of collagen fibre content. Glycosaminoglycans remained stable, no significant alterations of α-SMA or CD31 epitopes and no accumulation of calciumhydroxyapatite were observed after 14 days of incubation. CONCLUSIONS: The presented ex vivo MPS allows long-term AV tissue incubation and will be adopted for future investigation of CAVD pathophysiology, also implementing human tissues. The bimodal viability assessment and ECM analyses approve reliability of ex vivo CAVD investigation and comparability of parallel tissue segments with different treatment strategies regarding the AV (patho)physiology.

3.
Antonie Van Leeuwenhoek ; 116(12): 1285-1294, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37751033

RESUMO

Methylorubrum extorquens is an important model methylotroph and has enormous potential for the development of C1-based microbial cell factories. During strain construction, regulated promoters with a low background expression level are important genetic tools for expression of potentially toxic genes. Here we present an accordingly optimised promoter, which can be used for that purpose. During construction and testing of terpene production strains harbouring a recombinant mevalonate pathway, strong growth defects were observed which made strain development impossible. After isolation and characterisation of suppressor mutants, we discovered a variant of the cumate-inducible promoter PQ2148 used in this approach. Deletion of 28 nucleotides resulted in an extremely low background expression level, but also reduced the maximal expression strength to about 30% of the original promoter. This tightly repressed promoter version is a powerful module for controlled expression of potentially toxic genes in M. extorquens.


Assuntos
Methylobacterium extorquens , Regiões Promotoras Genéticas , Methylobacterium extorquens/genética , Methylobacterium extorquens/metabolismo , Metanol/metabolismo
4.
Biomedicines ; 11(7)2023 Jul 20.
Artigo em Inglês | MEDLINE | ID: mdl-37509683

RESUMO

Despite disadvantages, such as high cost and their poor predictive value, animal experiments are still the state of the art for pharmaceutical substance testing. One reason for this problem is the inability of standard cell culture methods to emulate the physiological environment necessary to recapitulate in vivo processes. Microphysiological systems offer the opportunity to close this gap. In this study, we utilize a previously employed microphysiological system to examine the impact of pressure and flow on the transportation of substances mediated by multidrug resistance protein 1 (MDR1) across an artificial cell-based tubular barrier. By using a miniaturized fluorescence measurement device, we could continuously track the MDR1-mediated transport of rhodamine 123 above the artificial barrier over 48 h. We proved that applying pressure and flow affects both active and passive transport of rhodamine 123. Using experimental results and curve fittings, the kinetics of MDR1-mediated transport as well as passive transport were investigated; thus, a kinetic model that explains this transport above an artificial tubular barrier was identified. This kinetic model demonstrates that the simple Michaelis-Menten model is not an appropriate model to explain the MDR1-mediated transport; instead, Hill kinetics, with Hill slope of n = 2, is a better fit. The kinetic values, Km, Vmax, and apparent permeability (Papp), obtained in this study are comparable with other in vivo and in vitro studies. Finally, the presented proximal tubule-on-a-chip can be used for pharmaceutical substance testing and to investigate pharmacokinetics of the renal transporter MDR1.

5.
Adv Healthc Mater ; 12(28): e2301300, 2023 11.
Artigo em Inglês | MEDLINE | ID: mdl-37498721

RESUMO

Device-associated bloodstream infections can cause serious medical problems and cost-intensive postinfection management, defining a need for more effective antimicrobial coatings. Newly developed coatings often show reduced bacterial colonization and high hemocompatibility in established in vitro tests, but fail in animal studies or clinical trials. The poor predictive power of these models is attributed to inadequate representation of in vivo conditions. Herein, a new single-pass blood flow model, with simultaneous incubation of the test surface with bacteria and freshly-drawn human blood, is presented. The flow model is validated by comparative analysis of a recently developed set of antiadhesive and contact-killing polymer coatings, and the corresponding uncoated polycarbonate surfaces. The results confirm the model's ability to differentiate the antimicrobial activities of the studied surfaces. Blood activation data correlate with bacterial surface coverage: low bacterial adhesion is associated with low inflammation and hemostasis. Shear stress correlates inversely with bacterial colonization, especially on antiadhesive surfaces. The introduced model is concluded to enable the evaluation of novel antimicrobial materials under in vivo-like conditions, capturing interactions between bacteria and biomaterials surfaces in the presence of key components of the ex vivo host response.


Assuntos
Anti-Infecciosos , Animais , Humanos , Anti-Infecciosos/farmacologia , Materiais Biocompatíveis , Aderência Bacteriana , Polímeros , Bactérias , Materiais Revestidos Biocompatíveis/farmacologia , Antibacterianos
6.
Biomater Biosyst ; 8: 100067, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36824376

RESUMO

Fiber-shaped materials have great potential for tissue engineering applications as they provide structural support and spatial patterns within a three-dimensional construct. Here we demonstrate the fabrication of mechanically stable, meter-long collagen hollow filaments by a direct extrusion printing process. The fibres are permeable for oxygen and proteins and allow cultivation of primary human endothelial cells (ECs) at the inner surface under perfused conditions. The cells show typical characteristics of a well-organized EC lining including VE-cadherin expression, cellular response to flow and ECM production. The results demonstrate that the collagen tubes are capable of creating robust soft tissue filaments. The mechanical properties and the biofunctionality of these collagen hollow filaments facilitate the engineering of prevascularised tissue engineering constructs.

7.
Acta Biomater ; 102: 273-286, 2020 01 15.
Artigo em Inglês | MEDLINE | ID: mdl-31778832

RESUMO

The lack of a fully developed human cardiac model in vitro hampers the progress of many biomedical research fields including pharmacology, developmental biology, and disease modeling. Currently, available methods may only differentiate human induced pluripotent stem cells (iPSCs) into immature cardiomyocytes. To achieve cardiomyocyte maturation, appropriate modulation of cellular microenvironment is needed. This study aims to optimize a microfluidic system that enhances maturation of human iPSC-derived cardiomyocytes (iPSC-CMs) through cyclic pulsatile hemodynamic forces. Human iPSC-CMs cultured in the microfluidic system show increased alignment and contractility and appear more rod-like shaped with increased cell size and increased sarcomere length when compared to static cultures. Increased complexity and density of the mitochondrial network in iPSC-CMs cultured in the microfluidic system are in line with expression of mitochondrial marker genes MT-CO1 and OPA1. Moreover, the optimized microfluidic system is capable of stably maintaining controlled oxygen levels and inducing hypoxia, revealed by increased expression of HIF1α and EGLN2 as well as changes in contraction parameters in iPSC-CMs. In summary, this microfluidic system boosts the structural maturation of iPSC-CM culture and could serve as an advanced in vitro cardiac model for biomedical research in the future. STATEMENT OF SIGNIFICANCE: The availability of in vitro human cardiomyocytes generated from induced pluripotent stem cells (iPSCs) opens the possibility to develop human in vitro heart models for disease modeling and drug testing. However, iPSC-derived cardiomyocytes remain structurally and functionally immature, which hinders their application. In this manuscript, we present an optimized and complete microfluidic system that enhances maturation of iPSC-derived cardiomyocytes through physiological cyclic pulsatile hemodynamic forces. Furthermore, we improved our microfluidic system by using a closed microfluidic recirculation and oxygen exchangers to achieve and maintain low oxygen in the culture chambers, which is suitable for mimicking the hypoxic condition and studying the pathophysiological mechanisms of human diseases in vitro. In the future, a variety of technologies including 3D tissue engineering could be integrated into our system, which may greatly extend the use of iPSC-derived cardiac models in drug development and disease modeling.


Assuntos
Diferenciação Celular/fisiologia , Células-Tronco Pluripotentes Induzidas/fisiologia , Microfluídica/métodos , Miócitos Cardíacos/fisiologia , Biomimética/instrumentação , Biomimética/métodos , Hipóxia Celular/fisiologia , Humanos , Células-Tronco Pluripotentes Induzidas/citologia , Microfluídica/instrumentação , Miócitos Cardíacos/citologia
8.
Biosensors (Basel) ; 8(3)2018 Jul 25.
Artigo em Inglês | MEDLINE | ID: mdl-30044392

RESUMO

Optical biosensors based on one-dimensional photonic crystals sustaining Bloch surface waves are proposed to study antibody interactions and perform affinity studies. The presented approach utilizes two types of different antibodies anchored at the sensitive area of a photonic crystal-based biosensor. Such a strategy allows for creating two or more on-chip regions with different biochemical features as well as studying the binding kinetics of biomolecules in real time. In particular, the proposed detection system shows an estimated limit of detection for the target antibody (anti-human IgG) smaller than 0.19 nM (28 ng/mL), corresponding to a minimum surface mass coverage of 10.3 ng/cm². Moreover, from the binding curves we successfully derived the equilibrium association and dissociation constants (KA = 7.5 × 107 M-1; KD = 13.26 nM) of the human IgG⁻anti-human IgG interaction.


Assuntos
Anticorpos/análise , Técnicas Biossensoriais/métodos , Imunoglobulina G/análise , Nanoestruturas/química , Óptica e Fotônica/métodos , Fótons , Anticorpos/imunologia , Técnicas Biossensoriais/instrumentação , Humanos , Imunoglobulina G/imunologia , Óptica e Fotônica/instrumentação
9.
Biomed Opt Express ; 9(2): 529-542, 2018 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-29552391

RESUMO

Quantitative detection of angiogenic biomarkers provides a powerful tool to diagnose cancers in early stages and to follow its progression during therapy. Conventional tests require trained personnel, dedicated laboratory equipment and are generally time-consuming. Herein, we propose our developed biosensing platform as a useful tool for a rapid determination of Angiopoietin-2 biomarker directly from patient plasma within 30 minutes, without any sample preparation or dilution. Bloch surface waves supported by one dimensional photonic crystal are exploited to enhance and redirect the fluorescence arising from a sandwich immunoassay that involves Angiopoietin-2. The sensing units consist of disposable and low-cost plastic biochips coated with the photonic crystal. The biosensing platform is demonstrated to detect Angiopoietin-2 in plasma samples at the clinically relevant concentration of 6 ng/mL, with an estimated limit of detection of approximately 1 ng/mL. This is the first Bloch surface wave based assay capable of detecting relevant concentrations of an angiogenic factor in plasma samples. The results obtained by the developed biosensing platform are in close agreement with enzyme-linked immunosorbent assays, demonstrating a good accuracy, and their repeatability showed acceptable relative variations.

10.
ACS Synth Biol ; 7(1): 86-97, 2018 01 19.
Artigo em Inglês | MEDLINE | ID: mdl-29216425

RESUMO

The ethylmalonyl-CoA pathway (EMCP) is an anaplerotic reaction sequence in the central carbon metabolism of numerous Proteo- and Actinobacteria. The pathway features several CoA-bound mono- and dicarboxylic acids that are of interest as platform chemicals for the chemical industry. The EMCP, however, is essential for growth on C1 and C2 carbon substrates and therefore cannot be simply interrupted to drain these intermediates. In this study, we aimed at reengineering central carbon metabolism of the Alphaproteobacterium Methylobacterium extorquens AM1 for the specific production of EMCP derivatives in the supernatant. Establishing a heterologous glyoxylate shunt in M. extorquens AM1 restored wild type-like growth in several EMCP knockout strains on defined minimal medium with acetate as carbon source. We further engineered one of these strains that carried a deletion of the gene encoding crotonyl-CoA carboxylase/reductase to demonstrate in a proof-of-concept the specific production of crotonic acid in the supernatant on a defined minimal medium. Our experiments demonstrate that it is in principle possible to further exploit the EMCP by establishing an alternative central carbon metabolic pathway in M. extorquens AM1, opening many possibilities for the biotechnological production of EMCP-derived compounds in future.


Assuntos
Acil Coenzima A/genética , Proteínas de Bactérias/genética , Carbono/metabolismo , Glioxilatos/metabolismo , Engenharia Metabólica , Methylobacterium extorquens/metabolismo , Ácido Acético/metabolismo , Acil Coenzima A/deficiência , Acil-CoA Desidrogenases/deficiência , Acil-CoA Desidrogenases/genética , Oxirredutases do Álcool/genética , Oxirredutases do Álcool/metabolismo , Proteínas de Bactérias/metabolismo , Crotonatos/metabolismo , Formiato Desidrogenases/genética , Formiato Desidrogenases/metabolismo , Isocitrato Liase/genética , Isocitrato Liase/metabolismo , Malato Sintase/genética , Malato Sintase/metabolismo , Metanol/química , Metanol/metabolismo , Methylobacterium extorquens/genética , Methylobacterium extorquens/crescimento & desenvolvimento , Oxirredução , Espectrofotometria
11.
Eng Life Sci ; 18(4): 263-268, 2018 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-32624905

RESUMO

In this work, an approach for SPR spectroscopy using the liSPR system is examined that combines signal amplification by PCR and magnetic nanoparticles in one injection step. Therefore, the synthesis of PCR products was performed on the beads similar to a solid-phase PCR, termed PCR-on-a-bead. The functionality of this PCR was proven using an enzymatic assay. For validation the detection of oligonucleotides by SPR, an asymmetric PCR product was investigated. A signal increase upon binding of the PCR product to the specific probes was observed. In addition, surface regeneration of the chip was examined and reuse for at least two times ascertained. Amplification of the SPR signal by magnetic beads was verified but no signal was detected for PCR products immobilized on particles prior to injection.

12.
Biosensors (Basel) ; 7(3)2017 Aug 17.
Artigo em Inglês | MEDLINE | ID: mdl-28817097

RESUMO

We report on the use of one-dimensional photonic crystals to detect clinically relevant concentrations of the cancer biomarker ERBB2 in cell lysates. Overexpression of the ERBB2 protein is associated with aggressive breast cancer subtypes. To detect soluble ERBB2, we developed an optical set-up which operates in both label-free and fluorescence modes. The detection approach makes use of a sandwich assay, in which the one-dimensional photonic crystals sustaining Bloch surface waves are modified with monoclonal antibodies, in order to guarantee high specificity during the biological recognition. We present the results of exemplary protein G based label-free assays in complex biological matrices, reaching an estimated limit of detection of 0.5 ng/mL. On-chip and chip-to-chip variability of the results is addressed too, providing repeatability rates. Moreover, results on fluorescence operation demonstrate the capability to perform high sensitive cancer biomarker assays reaching a resolution of 0.6 ng/mL, without protein G assistance. The resolution obtained in both modes meets international guidelines and recommendations (15 ng/mL) for ERBB2 quantification assays, providing an alternative tool to phenotype and diagnose molecular cancer subtypes.


Assuntos
Biomarcadores Tumorais/análise , Técnicas Biossensoriais/métodos , Técnicas de Diagnóstico Molecular/métodos , Imagem Óptica/métodos , Fótons , Receptor ErbB-2/análise , Técnicas Biossensoriais/instrumentação , Técnicas Biossensoriais/normas , Linhagem Celular Tumoral , Humanos , Limite de Detecção , Técnicas de Diagnóstico Molecular/instrumentação , Imagem Óptica/instrumentação , Imagem Óptica/normas , Reprodutibilidade dos Testes
13.
Biosens Bioelectron ; 92: 125-130, 2017 Jun 15.
Artigo em Inglês | MEDLINE | ID: mdl-28209555

RESUMO

We report on the use of one-dimensional photonic crystals to detect clinically relevant concentrations of ERBB2/neu/Her2 in cell lysates. ERBB2 is a pivotal breast cancer biomarker and targetable oncogenic driver associated with aggressive breast cancer subtypes. To quantitate soluble ERBB2, we developed an optical platform that combines label-free and fluorescence detection modes. Such platform makes use of a sandwich assay in which the one-dimensional photonic crystals sustaining Bloch surface waves are tailored with a monoclonal antibody for highly specific biological recognition (BSW biochip). In a second step, a second antibody to ERBB2 quantitatively detects the bound analyte. The strategy of the present approach takes advantage of the combination of label-free and fluorescence techniques, making bio-recognition more robust and sensitive. In the fluorescence operation mode, the platform can attain the limit of detection 0.3ng/mL (1.5pM) for ERBB2 in cell lysates. Such resolution meets the international guidelines and recommendations (15ng/mL) for diagnostic ERBB2 assays that in the future may help to more precisely assign therapies counteracting cancer cell proliferation and metastatic spread.


Assuntos
Técnicas Biossensoriais/instrumentação , Neoplasias da Mama/diagnóstico , Mama/patologia , Receptor ErbB-2/análise , Anticorpos Monoclonais/química , Biomarcadores Tumorais/análise , Linhagem Celular Tumoral , Desenho de Equipamento , Feminino , Fluorescência , Humanos , Dispositivos Lab-On-A-Chip , Limite de Detecção
14.
Micromachines (Basel) ; 8(8)2017 Aug 11.
Artigo em Inglês | MEDLINE | ID: mdl-30400437

RESUMO

Micro Physiological Systems (MPS), also known as Multi-Organ-Chip, Organ-on-a-Chip, or Body-on-a-Chip, are advanced microfluidic systems that allow the cultivation of different types of cells and tissue in just one common circuit. Furthermore, they thus can also adjust the interaction of these different tissues. Perspectival MPS will replace animal testing. For fast and flexible manufacturing and marking of MPS, a concept for a universal micromachining platform has been developed which provides the following latest key technologies: laser micro cutting of polymer foils, laser micro- and sub-micro-structuring of polymer foils, 3D printing of polymer components as well as optical inspection and online process control. The combination of different laser sources, processing optics, inspection systems, and print heads on multiple axes allows the change and exactly positioning to the workpiece during the process. Therewith, the realization of MPS including 3D printed components as well as direct laser interference patterned surfaces for well-defined cell adhesion and product protection is possible. Additional basic technologies for the generation of periodical line-like structures at polycarbonate foils using special Direct Laser Interference Patterning (DLIP) optics as well as for the 3D printing of fluid-tight cell culture reservoirs made of Acrylonitrile Butadiene Styrene directly onto polycarbonate microfluidics were established. A first prototype of the universal micromachining platform combining different lasers with Direct Laser Writing and DLIP is shown. With this laser micro cutting as well as laser micro-structuring of polycarbonate (PC) foils and therewith functionalization for MPS application could be successfully demonstrated.

15.
Eng Life Sci ; 17(12): 1264-1270, 2017 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-32624754

RESUMO

MiRNAs are endogenous noncoding RNA molecules. They play important gene-regulatory roles by binding to the mRNA of target genes thereby leading to either transcript degradation or translational repression. In virtually all diseases, distinct alterations of miRNA expression profiles have been found thus suggesting miRNAs as interesting biomarkers. Here, we present an SPR biosensor that utilizes disposable, injection-molded sensor chip/microfluidic hybrids combined with a lateral imaging optical system for parallel analysis of three one-dimensional spot arrays to detect miRNA-93. To increase the sensitivity of the biosensor we used two different amplification strategies. By adding an RNA-DNA-hybrid antibody for primary signal amplification, a limit of detection of 10 pmol/L was achieved. Based on that method we demonstrate the detection of miRNA-93 in total RNA lysate from HEK-293 cells. Utilizing an enzymatic signal amplification with Poly(A) polymerase, the sensitivity could be increased even further leading to a limit of detection of 1 fmol/L.

16.
Biofabrication ; 8(1): 015015, 2016 Feb 27.
Artigo em Inglês | MEDLINE | ID: mdl-26924825

RESUMO

Additive manufacturing (AM) allows the free form fabrication of three-dimensional (3D) structures with distinct external geometry, fitting into a patient-specific defect, and defined internal pore architecture. However, fabrication of predesigned collagen scaffolds using AM-based technologies is challenging due to the low viscosity of collagen solutions, gels or dispersions commonly used for scaffold preparation. In the present study, we have developed a straightforward method which is based on 3D plotting of a highly viscous, high density collagen dispersion. The swollen state of the collagen fibrils at pH 4 enabled the homogenous extrusion of the material, the deposition of uniform strands and finally the construction of 3D scaffolds. Stabilization of the plotted structures was achieved by freeze-drying and chemical crosslinking with the carbodiimide EDC. The scaffolds exhibited high shape and dimensional fidelity and a hierarchical porosity consisting of macropores generated by strand deposition as well as an interconnected microporosity within the strands as result of the freeze-drying process. Cultivation of human mesenchymal stromal cells on the scaffolds, with and without adipogenic or osteogenic stimulation, revealed their cytocompatibility and potential applicability for adipose and bone tissue engineering.


Assuntos
Adipogenia/fisiologia , Colágeno/química , Células-Tronco Mesenquimais/citologia , Osteogênese/fisiologia , Impressão Tridimensional , Tecidos Suporte , Regeneração Óssea/fisiologia , Diferenciação Celular/fisiologia , Células Cultivadas , Módulo de Elasticidade , Desenho de Equipamento , Análise de Falha de Equipamento , Humanos , Teste de Materiais , Células-Tronco Mesenquimais/fisiologia , Propriedades de Superfície , Resistência à Tração , Viscosidade
17.
Curr Med Res Opin ; 32(3): 417-26, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-26568400

RESUMO

AIMS: Disease management programs (DMP) for diabetes mellitus (DM) or coronary heart disease (CHD) address the treatment of lipid disorders. The current registry aimed to compare drug utilization, lipid lowering effects and further outcomes of outpatients at high cardiovascular risk in DMP for DM or CHD compared to patients in routine care (no-DMP). METHODS: This was a prospective non-interventional registry with a 1 year follow-up which enrolled consecutive patients with known DM and/or any vascular disease on simvastatin 40 mg monotherapy, to document lipid target achievement in clinical practice in Germany according to existing guidelines. Drug use (maintenance, add-on, switch, discontinuation) and other components of care were upon the discretion of the treating physician. RESULTS: Of a total of 12,154 patients (mean age 65.8 years, 61.2% males), 3273 were in DMP CHD, 3265 in DMP DM and 1760 in DMP CHD + DM. In DMP patients compared to no-DMP patients, comorbidities/risk factors were more frequent. More patients in the DMP groups attained the target level of low density lipoprotein (LDL-C) <70 mg/dl (1.8 mmol/l) at baseline (8.5% DMP vs. 5.7% no-DMP), at 6 month (10.3% vs. 7.4%) and 12 month follow-up (10.1% vs. 7.1%). Cholesterol absorption inhibitors were added in 16% of the patients at the end of the baseline or at the follow-up visits, while statin treatment (including mean dose) remained largely unchanged. Target achievement rates were highest for all time points in the DMP CHD + DM group. With respect to limitations, this study was restricted to lipid disorders as qualifying diagnosis and simvastatin as qualifying treatment, which is a potential cause of selection bias. Information on non-pharmacological measures was not collected, and the 12-month follow-up period was relatively short. CONCLUSION: Patients in DMP compared to those not in DMP achieved better LDL-C lowering and higher control rates, but overall lipid target achievement rates need to be improved. Longer-term observations are needed to corroborate these findings.


Assuntos
Doenças Cardiovasculares/prevenção & controle , Doença da Artéria Coronariana/tratamento farmacológico , Diabetes Mellitus/tratamento farmacológico , Lipídeos/sangue , Adulto , Idoso , Idoso de 80 Anos ou mais , Anticolesterolemiantes/uso terapêutico , LDL-Colesterol/sangue , Feminino , Alemanha , Humanos , Inibidores de Hidroximetilglutaril-CoA Redutases/uso terapêutico , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Sistema de Registros , Fatores de Risco , Prevenção Secundária , Sinvastatina/uso terapêutico , Adulto Jovem
18.
Metab Eng ; 32: 82-94, 2015 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-26369439

RESUMO

Over the last 10 to 15 years, metabolic engineering of microbes has become a versatile tool for high-level de novo synthesis of terpenoids, with the sesquiterpenoids armopha-1,4-diene, farnesene and artemisinic acid as prime examples. However, almost all cell factory approaches towards terpenoids to date have been based on sugar as the raw material, which is mainly used as a food resource and subject to high price volatilities. In this study we present de novo synthesis of the sesquiterpenoid α-humulene from the abundantly available non-food carbon source methanol by metabolically engineered Methylobacterium extorquens AM1. Expression of α-humulene synthase from Zingiber zerumbet in combination with farnesyl pyrophosphate (FPP) synthase from Saccharomyces cerevisiae led to concentrations of up to 18 mg/L α-humulene. Introduction of a prokaryotic mevalonate pathway from Myxococcus xanthus in combination with ribosome binding site optimization of α-humulene and FPP synthases increased product concentration 3-fold. This value was additionally raised by 30% using a carotenoid synthesis deficient mutant strain. Final product concentrations of up to 1.65 g/L were obtained in methanol limited fed-batch cultivations, which is the highest titer of de novo synthesized α-humulene reported to date. This study demonstrates the potential of M. extorquens as a future platform strain for the production of high-value terpenoids from the alternative carbon source methanol.


Assuntos
Engenharia Metabólica/métodos , Metanol/metabolismo , Methylobacterium extorquens/genética , Methylobacterium extorquens/metabolismo , Sesquiterpenos/metabolismo , Reatores Biológicos , Carotenoides/biossíntese , Simulação por Computador , Meios de Cultura , Fermentação , Redes e Vias Metabólicas/genética , Ácido Mevalônico/metabolismo , Sesquiterpenos Monocíclicos , Plasmídeos
19.
Lab Chip ; 15(12): 2688-99, 2015 Jun 21.
Artigo em Inglês | MEDLINE | ID: mdl-25996126

RESUMO

Systemic absorption and metabolism of drugs in the small intestine, metabolism by the liver as well as excretion by the kidney are key determinants of efficacy and safety for therapeutic candidates. However, these systemic responses of applied substances lack in most in vitro assays. In this study, a microphysiological system maintaining the functionality of four organs over 28 days in co-culture has been established at a minute but standardized microsystem scale. Preformed human intestine and skin models have been integrated into the four-organ-chip on standard cell culture inserts at a size 100,000-fold smaller than their human counterpart organs. A 3D-based spheroid, equivalent to ten liver lobules, mimics liver function. Finally, a barrier segregating the media flow through the organs from fluids excreted by the kidney has been generated by a polymeric membrane covered by a monolayer of human proximal tubule epithelial cells. A peristaltic on-chip micropump ensures pulsatile media flow interconnecting the four tissue culture compartments through microfluidic channels. A second microfluidic circuit ensures drainage of the fluid excreted through the kidney epithelial cell layer. This four-organ-chip system assures near to physiological fluid-to-tissue ratios. In-depth metabolic and gene analysis revealed the establishment of reproducible homeostasis among the co-cultures within two to four days, sustainable over at least 28 days independent of the individual human cell line or tissue donor background used for each organ equivalent. Lastly, 3D imaging two-photon microscopy visualised details of spatiotemporal segregation of the two microfluidic flows by proximal tubule epithelia. To our knowledge, this study is the first approach to establish a system for in vitro microfluidic ADME profiling and repeated dose systemic toxicity testing of drug candidates over 28 days.


Assuntos
Técnicas de Cocultura/instrumentação , Rim/citologia , Fígado/citologia , Técnicas Analíticas Microfluídicas/instrumentação , Modelos Biológicos , Pele/citologia , Linhagem Celular , Células Cultivadas , Técnicas de Cocultura/métodos , Desenho de Equipamento , Perfilação da Expressão Gênica , Humanos , Rim/metabolismo , Fígado/metabolismo , Pele/metabolismo , Testes de Toxicidade
20.
J Vis Exp ; (98): e52526, 2015 Apr 28.
Artigo em Inglês | MEDLINE | ID: mdl-25992921

RESUMO

The ever growing amount of new substances released onto the market and the limited predictability of current in vitro test systems has led to a high need for new solutions for substance testing. Many drugs that have been removed from the market due to drug-induced liver injury released their toxic potential only after several doses of chronic testing in humans. However, a controlled microenvironment is pivotal for long-term multiple dosing experiments, as even minor alterations in extracellular conditions may greatly influence the cell physiology. We focused within our research program on the generation of a microengineered bioreactor, which can be dynamically perfused by an on-chip pump and combines at least two culture spaces for multi-organ applications. This circulatory system mimics the in vivo conditions of primary cell cultures better and assures a steadier, more quantifiable extracellular relay of signals to the cells. For demonstration purposes, human liver equivalents, generated by aggregating differentiated HepaRG cells with human hepatic stellate cells in hanging drop plates, were cocultured with human skin punch biopsies for up to 28 days inside the microbioreactor. The use of cell culture inserts enables the skin to be cultured at an air-liquid interface, allowing topical substance exposure. The microbioreactor system is capable of supporting these cocultures at near physiologic fluid flow and volume-to-liquid ratios, ensuring stable and organotypic culture conditions. The possibility of long-term cultures enables the repeated exposure to substances. Furthermore, a vascularization of the microfluidic channel circuit using human dermal microvascular endothelial cells yields a physiologically more relevant vascular model.


Assuntos
Técnicas de Cocultura/instrumentação , Fígado/citologia , Microfluídica/instrumentação , Pele/citologia , Biópsia , Reatores Biológicos , Diferenciação Celular/fisiologia , Técnicas de Cocultura/métodos , Células Endoteliais/citologia , Humanos , Microfluídica/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...